Software Upgrade
Loading Software onto the CFC
officer SEC>> get file cfc24_6.0.tar tftp server XXX.XXX.XXX.XXX
officer SEC>> get file fe10_6.0.tar tftp server XXX.XXX.XXX.XXX
Assigning SW loads to cards
officer SEC>> set card inactcfc temp cfc24_6.0.tar (for duplex MAP)
officer SEC>> set card actcfc temp cfc24_6.0.tar (for simplex MAP)
officer SEC>> set card XX temp XXXX_6.0.Xtar
Upgrade Procedure
(Hitless upgrade for Duplex MAP)
officer SEC>> restart card inactcfc
Note: After the inactcfc card comes back online it will be upgraded
officer SEC>> swap activity
(regular upgrade for simplex MAP)
officer SEC>> restart card actcfc
officer SEC>> show card actcfc software
observe output(check what software load is set for the running load)
officer SEC>> set card actcfc pref cfc24_6.0.tar
officer SEC>> restart card 1-3,4,8