SIMPLEX (one CFC)
- Run a database backup of the iMAP via CLI and save to the NMS
- backup database file backup_20150514 tftp server 10.10.10.10 [NMS IP address]
- backup file will be saved to C:\Program Files\Allied Telesis\AlliedView NMS\tftp
- download/transfer .tar software files for CFC and Service Modules to the NMS
- place new files in C:\Program Files\Allied Telesis\AlliedView NMS\tftp
- From the iMAP, initiate TFTP download of the software files from the NMS
- get file cfc100_18.0.1.tar tftp server 10.10.10.10
- get file fe10_18.0.1.tar tftp server 10.10.10.10
- (to verify) show file
- set the new software as the tempload for the CFC
- set card actcfc tempload cfc100_18.0.1.tar
- show card actcfc
- restart the CFC
- The CFC will reset.This can take up to 10 minutes.
- Once back online, verify the running load is the new software
- Following the same basic procedure, upgrade one or multiple service modules
- set card 4,5,6,12 tempload fe10_18.0.1.tar
- restart card 4,5,6,12 cold
- (to verify) show card
- Verify services are operating normally
- Set the preferred loads on all other cards to the new software
- set card actcfc prefload cfc100_18.0.1.tar
- set card 4,5,6,12 prefload fe10_18.0.1.tar
- show card software
DUPLEX (dual CFC's)
- Run a database backup of the iMAP via CLI and save to the NMS
- backup database file backup_20150514 tftp server 10.10.10.10
- backup file will be saved to C:\Program Files\Allied Telesis\AlliedView NMS\tftp
- download .tar software files for CFC and Service Modules to the NMS
- place new files in C:\Program Files\Allied Telesis\AlliedView NMS\tftp
- TFTP the software files from the NMS to the iMAP
- get file cfc100_18.0.1.tar tftp server 10.10.10.10
- get file fe10_18.0.1.tar tftp server 10.10.10.10
- (to verify) show file
- set the new software as the tempload for the inactive CFC
- set card inactcfc tempload cfc100_18.0.1.tar
- show card inactcfc
- restart the inactive CFC
- restart card inactcfc cold --or-- disable inactcfc [then…] enable inactcfc
- The CFC will reset.This can take up to 10 minutes.Wait until the Out of Sync alarm has cleared.
- Once back online, verify the running load on the inactive CFC is the new software
- Switch CFC functions to the inactive CFC
- swap activity
- (to verify) show card
- Following the same basic procedure, upgrade one or multiple service modules
- set card 4,5,6,12 tempload fe10_18.0.1.tar
- restart card 4,5,6,12 cold
- (to verify) show card
- Verify services are operating normally across cards that have been upgraded
- Set the preferred load on the active CFC and all other cards to the new software
- set card actcfc prefload cfc100_18.0.1.tar
- show card software
|